Unit number. Building name. House number. I agree for Bosch Thermotechnology Ltd. New products and promotions, including information about our Reward Scheme. Information about products of our other group companies e. Surveys and market research. Installer's Choice newsletter. Events, including installer training updates. Note: Top and bottom clearances must not be reduced below these values as they are the minimum required for servicing.
This boiler is only suitable for installing internally within a property at a suitable location onto a fixed, rigid non-combustible surface at least the same size as the boiler and capable of supporting the boiler weight. The diagram opposite shows the minimum space required to install and service the boiler. If a boiler is installed in a compartment with clearances less than shown in the tables opposite, ventilation is required.
Refer to tables below for ventilation requirements. The tables opposite show the options for the minimum space required to install and service the boiler inside an unventilated compartment. If the appliance is fitted in conjunction with a mechanical or R F mechanical timer, the.
Electrical switches, fused spur and socket outlets must not be situated in the bathroom. This is fitted to the boiler frame. Further guidance on pipe routing can be found printed on the boiler template supplied with the boiler.
Minimum dimensions of flue terminal positions for balanced room sealed flues with fanned draught:. This could be a nuisance, for example, near security lighting. The guard must be spaced equally minimum 50mm around the flue and fixed to the wall with plated screws. Contact your supplier or Worcester. Measure the total flue length required, noting that the maximum straight flue length including the terminal is:. Then reduce the total straight flue length for each extra flue bend excluding the flue elbow by:.
Welcome to ManualMachine. We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions. Enter a new password.
British Standards: The relevant British Standards should be followed, including: BS : Code of practice for domestic and hot water supply B S : Installation of low pressure gas pipework up to 28mm R1 BS : Installation of gas hot water supplies for domestic purposes EN : Central heating for domestic premises BS : Flues and ventilation for gas appliances of rated heating not exceeding 70kW net : Flues BS : Flues and ventilation for gas appliances of rated heating not exceeding 70kW net : Air Supply BS : Treatment of water in domestic hot water central heating systems BS : Installation of gas fired boilers of rated input up to 70kW net Where no specific instruction is given, reference should be made to the relevant British Standard codes of Practice.
Installation: An appliance using L. Potable water: All seals, joints and compounds including flux and solder and components used as part of the secondary domestic water system must be approved by WRAS.
CH water: Artificially softened water must not be used to fill the central heating system. How efficient is the Greenstar 24i? As a result, you could see your heating bills drop rather considerably. In Stock - Next Day Delivery. This part fits. You can then pinch zoom to adjust the size. Worcester part no. Worcester Bosch Greenstar Junior 24i poor hot water pressure.
Posted on 19 Mar Owner of this Worcester Greenstar Junior 24i complained about very poor hot water flow from taps in his kitchen and bathroom. When I got to site and tested existing flow on this boiler I measured 5 liters a minute in the kitchen and liters a minute.
Enhance your purchase. Greenstar 24i junior. Discussion in Plumbers Talk. It its an involved job,leave enough time to do it and be prepared for the worcester suprise. Worcester Bosch Greenstar i Junior Combi Boilers is especially designed for modern apartments and small to medium sized properties with one bathroom. Key features include a compact dimensions to save as much space as possible, and multi-directional fluing which gives siting flexibility.
Lightweight at Worcester Greenstar 24i system erp boiler Worcester Greenstar 25i Combi erp boiler Greenstar Junior 30i - 5-year manufacturer s warranty included. We have a worcester bosch greenstar 24i junior and it works fine on continuous heating but not now on timer. The Greenstar 24i junior is a Condensing Combi boiler with a maximum power output of 24kw that uses LPG as its fuel source. This boiler will provide efficient heating and subsequently reduce fuel bills and carbon dioxide emissions.
Best wireless thermostat for worcester greenstar 24i junior boiler We fitted a wireless thermostat last summer THD which worked perfectly until a couple of months ago.
The transmitter no longer talks to the receiver, and we think it s the receiver that isn t working properly now as the lights don t come on properly. This manual also for: Flue Terminal Positions 50 mm around the flue and fixed to the wall with plated screws. Clean around sealing surface on sump and replace access cover P.
Manyal the best energy tariff for you Get a quote. Worcester Bosch. Hi all, I have a Worcester Greenstar 24i Junior combi boiler and I want to fit a Hive 2 heating and hot water thermostat.
I realise that I ve bought the wrong version but I d rather make do with what I have instead of having to send it back to get the heating only version.
Worcester 28i Junior Boiler Spares. Worcester Greenstar 15i Boiler Spares. Worcester Greenstar 24I System. Dec 24, Listed below are all the manuals for Worcester. Just click on the model or the Gas council number and the manual will download at the bottom of the page. After you have downloaded the manual double click on the download for the manual to open, if you want to save the download right click. The isolator must have a contact separation of 3mm minimum in all poles. Turn the boiler thermostat control C to maximum.
Wall hung gas-fired condensing combination boiler 21 pages. Switch on the mains electricity. Page 50 To refit, follow the above in reverse. The Greenstar 24i System is a Condensing Conventional boiler with a maximum power output of 24kw that uses Gas as its fuel source.
Part No: - Fully Refurbished. Quality ensured by our experienced engineers. It will be necessary to run water through the DHW circuit to ensure that the boiler will not cycle on low heating demands.
Page 40 Remove stainless steel viewing mirror F. Lift up assembly and remove from boiler. Disconnect spark electrode and flame sensor connections J. Remove clamping plate K. Page 41 Clean around sealing surface on sump and replace access cover P.
Using a suitable container to collect water from syphon connection at the base of the boiler flush heat exchanger with water. Re-assemble ensuring that the lower baffle N and the top baffle M are refitted correctly. Removing outer case 1. To remove bottom tray, pull forward on the tag on the underside of the tray. Page 43 Pull valve up and forward out of boiler. Disconnect electrical connections. Replace valve with new seals and check for gas soundness. Isolate gas supply at boiler gas cock.
Page 44 T2. Access to boiler control components Remove 3 screws A and remove cover from control. Page 45 E upwards and slide the control support bracket F to the left. Remove the support cable and fit to the new control. Remove appropriate cable restraints from the new control box.
Pressure switch Page Replacement Of Parts Pull heat exchanger assembly up to clear. Diverter valve motor